45 research outputs found

    Patient-specific CFD simulation of intraventricular haemodynamics based on 3D ultrasound imaging

    Get PDF
    Background: The goal of this paper is to present a computational fluid dynamic (CFD) model with moving boundaries to study the intraventricular flows in a patient-specific framework. Starting from the segmentation of real-time transesophageal echocardiographic images, a CFD model including the complete left ventricle and the moving 3D mitral valve was realized. Their motion, known as a function of time from the segmented ultrasound images, was imposed as a boundary condition in an Arbitrary Lagrangian-Eulerian framework. Results: The model allowed for a realistic description of the displacement of the structures of interest and for an effective analysis of the intraventricular flows throughout the cardiac cycle. The model provides detailed intraventricular flow features, and highlights the importance of the 3D valve apparatus for the vortex dynamics and apical flow. Conclusions: The proposed method could describe the haemodynamics of the left ventricle during the cardiac cycle. The methodology might therefore be of particular importance in patient treatment planning to assess the impact of mitral valve treatment on intraventricular flow dynamics

    In-vivo heterogeneous functional and residual strains in human aortic valve leaflets

    Get PDF
    Residual and physiological functional strains in soft tissues are known to play an important role in modulating organ stress distributions. Yet, no known comprehensive information on residual strains exist, or non-invasive techniques to quantify in-vivo deformations for the aortic valve (AV) leaflets. Herein we present a completely non-invasive approach for determining heterogeneous strains – both functional and residual – in semilunar valves and apply it to normal human AV leaflets. Transesophageal 3D echocardiographic (3DE) images of the AV were acquired from open-heart transplant patients, with each AV leaflet excised after heart explant and then imaged in a flattened configuration ex-vivo. Using an established spline parameterization of both 3DE segmentations and digitized ex-vivo images (Aggarwal et al., 2014), surface strains were calculated for deformation between the ex-vivo and three in-vivo configurations: fully open, just-coapted, and fully-loaded. Results indicated that leaflet area increased by an average of 20% from the ex-vivo to in-vivo open states, with a highly heterogeneous strain field. The increase in area from open to just-coapted state was the highest at an average of 25%, while that from just-coapted to fully-loaded remained almost unaltered. Going from the ex-vivo to in-vivo mid-systole configurations, the leaflet area near the basal attachment shrank slightly, whereas the free edge expanded by ~10%. This was accompanied by a 10° −20° shear along the circumferential-radial direction. Moreover, the principal stretches aligned approximately with the circumferential and radial directions for all cases, with the highest stretch being along the radial direction. Collectively, these results indicated that even though the AV did not support any measurable pressure gradient in the just-coapted state, the leaflets were significantly pre-strained with respect to the excised state. Furthermore, the collagen fibers of the leaflet were almost fully recruited in the just-coapted state, making the leaflet very stiff with marginal deformation under full pressure. Lastly, the deformation was always higher in the radial direction and lower along the circumferential one, the latter direction made stiffer by the preferential alignment of collagen fibers. These results provide significant insight into the distribution of residual strains and the in-vivo strains encountered during valve opening and closing in AV leaflets, and will form an important component of the tool that can evaluate valve׳s functional properties in a non-invasive manner

    Multimodal image analysis and subvalvular dynamics in ischemic mitral regurgitation

    Get PDF
    Background: The exact geometric pathogenesis of leaflet tethering in ischemic mitral regurgitation (IMR) and the relative contribution of each component of the mitral valve complex (MVC) remain largely unknown. In this study, we sought to further elucidate mitral valve (MV) leaflet remodeling and papillary muscle dynamics in an ovine model of IMR with magnetic resonance imaging (MRI) and 3-dimensional echocardiography (3DE). Methods: Multimodal imaging combining 3DE and MRI was used to analyze the MVC at baseline, 30 minutes post–myocardial infarction (MI), and 12 weeks post-MI in ovine IMR models. Advanced 3D imaging software was used to trace the MVC from each modality, and the tracings were verified against resected specimens. Results: 3DE MV remodeling was regionally heterogenous and observed primarily in the anterior leaflet, with significant increases in surface area, especially in A2 and A3. The posterior leaflet was significantly shortened in P2 and P3. Mean posteromedial papillary muscle (PMPM) volume was decreased from 1.9 ± 0.2 cm3 at baseline to 0.9 ± 0.3 cm3 at 12 weeks post-MI (P <.05). At 12 weeks post-MI, the PMPM was predominately displaced horizontally and outward along the intercommissural axis with minor apical displacement. The subvalvular contribution to tethering is a combination of unilateral movement, outward displacement, and degeneration of the PMPM. These findings have led to a proposed new framework for characterizing PMPM dynamics in IMR. Conclusions: This study provides new insights into the complex interrelated and regionally heterogenous valvular and subvalvular mechanisms involved in the geometric pathogenesis of IMR tethering

    Quantitative three-dimensional echocardiographic analysis of the bicuspid aortic valve and aortic root:A single modality approach

    Get PDF
    Background Patients with bicuspid aortic valves (BAV) are heterogeneous with regard to patterns of root remodeling and valvular dysfunction. Two-dimensional echocardiography is the standard surveillance modality for patients with aortic valve dysfunction. However, ancillary computed tomography or magnetic resonance imaging is often necessary to characterize associated patterns of aortic root pathology. Conversely, the pairing of three-dimensional (3D) echocardiography with novel quantitative modeling techniques allows for a single modality description of the entire root complex. We sought to determine 3D aortic valve and root geometry with this quantitative approach. Methods Transesophageal real-time 3D echocardiography was performed in five patients with tricuspid aortic valves (TAV) and in five patients with BAV. No patient had evidence of valvular dysfunction or aortic root pathology. A customized image analysis protocol was used to assess 3D aortic annular, valvular, and root geometry. Results Annular, sinus and sinotubular junction diameters and areas were similar in both groups. Coaptation length and area were higher in the TAV group (7.25 +/- 0.98 mm and 298 +/- 118 mm(2), respectively) compared to the BAV group (5.67 +/- 1.33 mm and 177 +/- 43 mm(2); P = .07 and P = .01). Cusp surface area to annular area, coaptation height, and the sub- and supravalvular tenting indices did not differ significantly between groups. Conclusions Single modality 3D echocardiography-based modeling allows for a quantitative description of the aortic valve and root geometry. This technique together with novel indices will improve our understanding of normal and pathologic geometry in the BAV population and may help to identify geometric predictors of adverse remodeling and guide tailored surgical therapy

    Automated quantification of mitral valve morphology and dynamics using real-time 3D echocardiography

    No full text
    Mitral valve repair has become the surgical treatment of choice in patients with mitral regurgitation (MR). However, recent long-term studies have indicated that the recurrence rate of significant MR after repair is much higher than previously thought. Disappointing clinical outcomes likely result from inadequate mitral valve assessment, a necessary step in predicting which patients will benefit from mitral valve repair over replacement and in identifying repair strategies that target patient-specific distortions in valve geometry. Physiological models of the mitral valve constructed from real-time 3D echocardiographic (rt-3DE) images can provide visual and quantitative information that allows for an optimized patient-specific approach to valve surgery. Rt-3DE is an ideal imaging modality for surgical guidance and overcomes many limitations of traditional two-dimensional echocardiography. While the current commercial rt-3DE platforms can acquire high-quality 3D images, these platforms do not provide fully automated quantification or spatially dense representations of valve geometry for interactive visualization. They require off-line user interaction and have limited potential for image-based surgical guidance. To overcome this limitation, this dissertation presents and validates both semi- and fully automated 3D mitral valve segmentation algorithms. The former method is based on user-initialized active contour evolution, while the latter makes use of fully automated multi-atlas label fusion. A unique feature of both algorithms is the use of template-based medial modeling to represent the mitral leaflets as structures with locally varying thickness. In the deformable medial modeling framework, each instance of the valve is mapped to a common shape-based coordinate system, which enables landmark identification and automated morphometry. The utility of the algorithms is demonstrated in three applications: statistical analysis of normal mitral annular geometry, 3D printing of image-derived mitral valve models, and estimation of leaflet stress distributions using image-based models as input to finite element analysis. Furthermore, the dissertation extends 3D mitral leaflet segmentation to 4D and proposes methods for improved spatiotemporal analysis of rt-3DE image data. The work is a step towards providing surgeons a practical tool for interactively visualizing and quantitatively assessing mitral valve morphology and dynamics in the peri-operative period, with the goal of improving long-term outcomes of surgical treatment for MR

    Local aortic aneurysm wall expansion measured with automated image analysis.

    No full text
    BACKGROUND: Assessment of regional aortic wall deformation (RAWD) might better predict for abdominal aortic aneurysm (AAA) rupture than the maximal aortic diameter or growth rate. Using sequential computed tomography angiograms (CTAs), we developed a streamlined, semiautomated method of computing RAWD using deformable image registration (dirRAWD). METHODS: Paired sequential CTAs performed 1 to 2 years apart of 15 patients with AAAs of various shapes and sizes were selected. Using each patient\u27s initial CTA, the luminal and aortic wall surfaces were segmented both manually and semiautomatically. Next, the same patient\u27s follow-up CTA was aligned with the first using automated rigid image registration. Deformable image registration was then used to calculate the local aneurysm wall expansion between the sequential scans (dirRAWD). To measure technique accuracy, the deformable registration results were compared with the local displacement of anatomic landmarks (fiducial markers), such as the origin of the inferior mesenteric artery and/or aortic wall calcifications. Additionally, for each patient, the maximal RAWD was manually measured for each aneurysm and was compared with the dirRAWD at the same location. RESULTS: The technique was successful in all patients. The mean landmark displacement error was 0.59 ± 0.93 mm with no difference between true landmark displacement and deformable registration landmark displacement by Wilcoxon rank sum test ( CONCLUSIONS: We found accurate and automated RAWD measurements were feasible with clinically insignificant errors. Using semiautomated AAA segmentations for deformable image registration methods did not alter maximal dirRAWD accuracy compared with using manual AAA segmentations. Future work will compare dirRAWD with finite element analysis-derived regional wall stress and determine whether dirRAWD might serve as an independent predictor of rupture risk
    corecore